![]() It is not necessary to change or add any interface cards to the exchange in order to use the DDS. The exchange does not need to be reconfigured or powered off. The DDS directly supports a -48V power input and a cable is supplied for this purpose. InstallationĪfter taking the legacy tape drive out of service using the AXE10 console, the old equipment can be disconnected from the SCSI bus and the DDS connected. Many additional features are provided such as virtual tapes, progress display, setting the SCSI ID and enabling cable error detection and correction.Įricsson backups use a checksum which helps to ensure data validity. ![]() The DDS supports Ericsson AXE10 Magnetic Tape Emulation via a directly-connected SCSI bus with terminal enabled or disabled in software as required. A single 50-pin conector is used for data, with a separate -48V power connector. Some special commands and features are enabled and must be supported by the device. The AXE10 makes use of a variant of SCSI, with single-ended signalling. It can take 4 hours to complete a backup and restore operation, even longer with a very large exchange. ![]() The Ericsson AXE10 has a large line capacity and therefore tape backups can be fairly large.